Thin underlay with integrated vapour barrier
Low installation heights and high requirements do go together. The SELITPRO® HD 1.5 mm AquaStop proves this. Despite its low thickness, it also protects your floor from high loads. Also impressive: the significant reduction in walking sound. To prevent residual moisture from causing damage, the SELITPRO® HD 1.5 has an integrated vapour barrier. It is also suitable for vinyl floors.
Heavy-duty film with mineral filling - Ideal for underfloor heating
Before installation, please note: check the base in accordance with CEN/TS 14472 and ensure that the quality of the base is suitable for proper processing. In general, the base should be clean, level, dry, resistant to tension and compression and should not contain any substances such as plasticisers, solvents or other diffusing substances. It must be ensured that the base is in a state of equilibrium humidity and that the CM value is below 2.0 % (for cement screed) or below 0.5 % (for anhydrite screed and anhydrite flowing screed). The processing instructions of the flooring manufacturer are to be observed as binding specifications.
Cleaning the surface
Cleaning the surface
Step 1 Clean the surface thoroughly with a brush or vacuum cleaner. Remove any adhesive and paint residues completely.
Laying out the first panel
Laying out the first panel
Step 2 Lay the first panel of the underlay flush with the wall over the entire width of the room. Make sure that the aluminium side is at the top.
Masking joints
Masking joints
Step 3 To protect against moisture, seal possible joints with SELITstop® Aluminium-Foil Sealing Tape to make the joints vapour-tight.
Masking the wall connection area
Masking the wall connection area
Step 4 To protect the wall connection area from moisture, we recommend the pre-notched SELITstop® Moulding Protection Belt.
Installing the laminate
Installing the laminate
Step 5 Lay the laminate in the same orientation as the underlay. Observe the manufacturer’s instructions and do not place any load on the underlay. If necessary, place the laminate board under your knees/feet to distribute the load.
Finishing the installation
Finishing the installation
Step 6 Repeat steps 2 – 5 until the entire floor has been installed. Tape the joints with the Aluminium-Foil Sealing Tape to make them vapour-tight.
Technicaldata(according to EN 16354)
Punctual conformability (PC)
up to 0.5 mm
Compressive strength (CS)
≥ 400 kPa
Compressive creep (CC)
≥ 25 kPa
Dynamic load (DL25)
≥ 250,000 cycles
Resistance to large ball (RLB)
≥ 30 cm
Water vapour diffusion resistance (SD)
≥ 100 m
Thermal resistance (R)
~ 0.010 m²K/W
Impact sound reduction (IS)
Laminate up to 16 dB | Vinyl up to 13 dB
Reaction to fire (RTF)
Efl
*Suitability for underfloor heating
Yes, if flooring R ≤ 0,14 m²K/W (e.g. laminate up to approx. 12 mm, wood flooring up to approx. 14 mm)
Meets the minimum requirements of the EPLF and MMFA (Group 1)