Versatile with moisture protection protection
SELITPRO 2.2® mm AquaStop reliably protects your floor from loads and damage caused by falling objects, reduces walking and impact sound and can be combined with underfloor heating. It also has an AquaStop+™ surface (sd value ≥ 200). This means that rising moisture has no chance of winning.
Highly resilient thanks to hybrid foam - an all-rounder with AquaStop™ surface
TwinFoam™ technology: Combination of 2 high-performance foams
Before installation, please note: Before installation, check the base in accordance with CEN/TS 14472 and ensure that the quality of the base is suitable for proper processing. In general, the base should be clean, level, dry, resistant to tension and compression and should not contain any substances such as plasticisers, solvents or other diffusing substances. It must be ensured that the base is in a state of equilibrium humidity and that the CM value is below 2.0 % (for cement screed) or below 0.5 % (for anhydrite screed and anhydrite flowing screed). The processing instructions of the flooring manufacturer are to be observed as binding specifications.
Cleaning the surface
Cleaning the surface
Step 1 Clean the surface thoroughly with a brush or vacuum cleaner. Remove any adhesive and paint residues completely.
Laying out the first panel
Laying out the first panel
Step 2 Lay the first panel of the underlay flush with the wall over the entire width of the room. Make sure that the aluminium side is at the top.
Masking joints
Masking joints
Step 3 To protect against moisture, seal possible joints with SELITstop® Aluminium-Foil Sealing Tape to make the joints vapour-tight.
Masking the wall connection area
Masking the wall connection area
Step 4 To protect the wall connection area from moisture, we recommend SELITstop® Moulding Protection Belt.
Installing the flooring
Installing the flooring
Step 5 Lay the flooring in the same orientation as the underlay. Do not place any load on the underlay. If necessary, place the board under your knees/feet to distribute the load.
Finishing the installation
Finishing the installation
Step 6 Repeat steps 2 – 5 until the entire floor has been installed. Connect the individual panels of the underlay using the easy click®+ contour. Tape the joints with the Aluminium-Foil Sealing Tape to make them vapour-tight.
Technicaldata(according to EN 16354)
Punctual conformability (PC)
up to 1 mm
Compressive strength (CS)
≥ 120 kPa
Compressive creep (CC)
≥ 25 kPa
Dynamic load (DL25)
≥ 1,000,000 cycles
Resistance to large ball (RLB)
≥ 120 cm
Water vapour diffusion resistance (SD)
≥ 200 m
Thermal resistance (R)
~ 0.07 m²K/W
Impact sound reduction (IS)
bis zu 21 dB
Reaction to fire (RTF)
Efl
*Suitability for underfloor heating
Yes, if flooring R ≤ 0,08 m²K/W (e.g. laminate up to approx. 10 mm, wood flooring up to approx. 12 mm)
Meets the increased requirements of the EPLF and MMFA (Group 1)